Whatman Biometra Fastblot B33

Sold
Wanted
SKU
Q106

Biometra Fastblot B33

Fastblot B33, plasticised carbon electrodes, with flow-through cooling

Cat # 014-100

Fast and homogeneous electrophoretic transfer of proteins Electrodes
Electrode material: plasticized carbon
Electrode sizes: 16 cm x 20 cm
Recommended for proteins up to 150 kDa
With Cooling option

Semi-dry blotting
Electro-blotting is an important method to transfer proteins and nucleic acids from polyacrylamide gels to nitrocellulose or other carrier membranes. Semi-dry blotting allows fast, efficient and homogenous transfer. In contrast to tank blotting little transfer buffer is required and transfer times are dramatically reduced. Additionally, with semi-dry blotting discontinuous buffer systems can be used, e.g. one cathode buffer and two different anode buffers, to gently blot smaller proteins or to transfer proteins of very different sizes evenly.

High capacity
All Fastblot models offer the capacity to transfer multiple gels: stacked (with a dialysis membrane separating the gel sandwiches) or side by side. There is no requirement for additional plastic templates to prevent electrode short circuit as necessary for use with other brands of semi-dry blotters.

Electrode material
The first graphite electrodes used for protein transfer corroded easily. Biometra permanently improved the blotting electrodes based on a novel bio-inert plasticised carbon material. This type of electrodes (used for models B33, B34) is stable for years.

Rapid transfer
Both, the plasticised carbon electrodes and the metal electrodes can be used for higher currents (max. 5 mA/cm2 blot). Therefore blotting times are reduced to as little as 10 to 30 minutes. By applying higher current (> 1 mA/cm2 blot), proteins with higher molecular weights can be blotted faster and with higher efficiency. Even smaller proteins can be transferred faster from thick gels and gels with small pores when blotting with high current.

Cooling option
Large proteins (> 100 kDa) require longer transfer times. The heat generated during the extended transfer time can be removed by using the flow-through cooling system which is available with models B33 and B43. Additionally this option is recommended for use with native gels and temperature sensitive proteins respectively.

Serial# 1910154