Hettich 32R Refrigerated Centrifuge
UNIVERSAL 32 means perfectly smooth running at both high and low speeds, versatile and easily
exchangeable accessories and small footprint.
This is why UNIVERSAL 32 centrifuges are requisitein every laboratory.
In the low speed range (max.RCF 4,193) the UNIVERSAL 32/32 Raccommodate standard tubes up
to a volume of 100 ml, microtitre plates, Falcon®* tubes, blood collection tubes and cyto accessories.
Microlitre tubes can be accelerated to a max. RCF of 23,907. Centrifuge tubes taking higher
volumes (up to 85 ml) also profit from the extraordinary motor power of the UNIVERSAL 32/32 R:
At an RCF of 9,418 bacteria and yeasts sediment fast and easily.
High RCF
85 ml tubes up to an RCF of 9,418, microlitre tubes up to an RCF of 23,907.
Extremely short run -up and run-down times also with rotors reaching higher speeds.
Efficient cooling
temperature in the UNIVERSAL 32 R is controllable within a range of -20°C to +40°C.
Special lid locking device
effortless closing and opening of the lid with one hand.
Ergonomically arranged controls and displays
Viewing port in the lid
3 complete running programmes can be stored and recalled
The fully developed up- to-date N control panel meets the requirements of the users and is extremely easy to operate.
Entry of the parameters is fast, precise and convenient with selector keys on the water- protected foil keypad.
The large display is well readable. During centrifugation the actual values of the parameters are indicated.
The parameters remain in the memory even after the centrifuge has been switched off.
Speed RPM: Input in increments of 10.
Relative centrifugal force RCF: Input in increments of 10.
Change-over RPM/RCF: By entering the rotor radius r/mm
the centrifuge calculates and indicates speed or RCF.
Running time t: Input in minutes and seconds, max. 99 min, 59 sec.
Run-up/ run-down times: Input of acceleration and braking ramps in levels 1– 9 or unbraked run-down.
Temperature T: With refrigerated models input in increments of 1OC within a range of -20 OC to +40 OC.
Memory: 3 complete running programmes can be stored and recalled.
Impulse key: For short centrifuging operations. The rotor spins at the preselected speed or RCF as long as the key remains pressed.
Supplied with rotor 1612 (12 tubes)
Dimensions (H xWx D): 300 x 420 x 660 mm
Serial Number: 0006858-02-00
SKU | Q130 |
---|---|
Availability | Out of Stock |
Condition | Used |