Artel PCS 3 Pipette Calibration System
Complete system including Manuals, printers, bar code reader, and Pipette Tracker Pro Software

Serial No: 7-10001
Model: PCS-103-07G

Date of Manufacture DEC 2014

Included:

  • Artel PCS
  • Honeywell Bar Code Reader
  • Pipette Tracker Pro Software, Full Installation and Client Version
  • Brother Label Printer PT-9700PC
  • Seiko Thermal Printer DPU 414
  • Procedure PDF Disc
  • Full set of Manuals
  • All cables/connections


PCS® Overview

The PCS is a fast, accurate, and precise system for verifying the volume dispensed from any single-channel pipette and calibrating single-channel pipettes. Portable and easy-to-use, the system is ready wherever and whenever you need it. Because the system uses ratiometric photometry and standardized dye solutions to determine the dispensed volumes, it is robust against differences in environmental conditions. Calibration results are traceable,1 enabling straightforward comparison of pipettes, operators, methods, and locations.


Optimize Pipetting Technique

  •     Perform fast and easy, calibrations and interim performance verification
  •     Improve pipetting proficiency and standardize technique with immediate feedback
  •     Calibrate pipettes in the location where they are used
  •     Verify pipette performance immediately before critical procedures and assays
  •     Verify pipette calibration following outsourced service
  •     Quickly check a pipette when a problem is suspected



CS® Features
PCS Instrument


Out-performs other calibration methods in consistency, speed, simplicity, accuracy and precision

— even at volumes as low as 0.1 µL.

    Calibration of single channel pipettes from 0.1 to 5,000 µL in less than three minutes
    Automatic accuracy and precision calculations
    Complete documentation and data management, including calibration audit trail, automatic printing of calibration labels, and trend analysis with graphical reporting
    Compact, portable instrument requiring minimal bench space and no special facilities or environmental controls
    Results traceable to national (NIST) and international standards
    Full compliance with 21 CFR Part 11, ISO 8655-7, CLIA.
    Method conforms to CLSI and the latest ISO standard (8655-7)


Pipette Tracker™ Software - PRO

Industry-leading pipette management software for tracking, analyzing pipette performance, and reporting status.

  •     Captures and stores results directly from PCS
  •     Tracks pipette inventory
  •     Schedules regular calibrations
  •     Customizable reports with trend analysis and graphical reporting
  •     Bar code label printing and scanning
  •     Calibration label printing


Additional features included with this Pipette Tracker™ Pro software

  •  
  •     Facilitates compliance with 21 CFR part 11 electronic records requirements
  •     Includes Validation Guide for IQ/OQ
  •     Alerts by email when pipettes are due for calibration
  •     Electronic signatures
  •     Complete audit trail

 

 



PCS® Specifications
System Performance

Assay Time Requirement                                           Three minutes for a ten data point calibration
Data Points Per Assay                                                 1 to 50 data points can be taken per calibration
Volume Range                                                               100 nL to 5000 µL
Inaccuracy                                                                      Less than 1%
Imprecision                                                                    Less than 0.5% CV
Operating Temperature                                              18 °C to 28 °C
Printed Output                                                                Complete calibration data record; 11.2 cm width; with
standard printer supplied

PCS Instrument
Size                                                                                   23 cm (9.1 in) W x 11.5 cm (4.5 in) H x 30.5 cm (12 in) D
Weight                                                                              4.8 kg (10.5 lbs.)
Keypad                                                                            18 keys
Display                                                                            2 X 20 alphanumeric
Wavelengths                                                                  520 nm and 730 nm
Printer Output                                                                Centronics Parallel
Serial I/O                                                                         RS 232 (configuration: 9600 bits per second, 8 data bits, 1 stop bit, no parity)
Noise                                                                              Less than 0.00015 AU at AU = 1
Inaccuracy                                                                      Less than 0.75% over the range 0 to 1.5 AU